The ARTROMOT-S4 Continuous Passive Motion shoulder machine is the result of 30 years of experience and more than 3 years of engineering

The ARTROMOT-S4 Continuous Passive Motion shoulder machine is the result of 30 years of experience in the shoulder CPM device business and more than 3 years of dedicated engineering, made in Germany.

Backed by three integrated motors, the new model from DJO Global supports the following movements:

  • Anteversion & retroversion
  • Adduction & abduction
  • Internal & external rotation
  • Extension & flexion (elevation) with extended or flexed arm
  • The combination of these motion axes enables anatomically correct PNF movements as well as the proven "wave" or undulation exercise.
  • Combined with the tried-and-tested features, such as the patient chip card and the sturdy design, the new ARTROMOT-S4 has even more therapy options to offer

Features and benefits: 

  • Touchscreen hand controller and motor controls for direct programming of motion ranges, with clear presentation and descriptive icons
  • 3 motors for all motion axes: anteversion & retroversion, adduction & abduction, internal & external rotation, extension & flexion (elevation) with extended or flexed arm
  • User guidance for easy conversion of the device for treatment of the right or left shoulder * Adaptive load reversal (reverse-on-load feature for patient safety/spasm protection), conforms automatically and sensitivity can be adjusted
  • Reinforced armrest with adjustable width and height

 Technical specifications:

  • Adduction/abduction: 0° / 30° / 160°
  • Anteversion/retroversion: 110° / 0° / 10°
  • Elevation (Ex/Flex): 0° / 30° / 160°
  • Internal/external rotation: 90° / 0° / 90°
  • Isolation: Enables separate exercises in all 3 directions of motion within a single treatment
  • Oscillation: Increases motion frequency in the EROM
  • PNF: Movements following the PNF pattern 
  • Stretching: Gently increases the range of motion
  • Wave: Undulating movements resembling a sideways figure eight 
  • Pulse frequency: 1 to 150 Hz
  • Weight 28 kg
  • Dimensions: 166 × 100 × 160 cm
  • Goniometer accuracy: ±2° 
  • Max. continuous load on motion element: 13 kg
  • Max. continuous load on seat: 175 kg
  • Patient height approx. 120 to 210 cm
  • Adaptive load reversal: 5-100 % of the trigger threshold tolerance range (reverse-on-load feature for patient safety/spasm protection)
  • Cycles: 5-20, adjustment of the Isolation, Oscillation and Stretching repetitions
  • Device setup: Adjustment of the basic settings (e.g., date, time or language)
  • Direction of the undulation: Adjustment of the direction of motion in Wave mode (Undulation)
  • Display mode: Toggles between detailed view and standard view
  • Head rest: For comfortable, optimal patient posture
  • Lockout functions: Locks individual functions, prevents accidental adjustment changes of set parameters and facilitates operation
  • Motor A, B and C ON/OFF: Isolated movements, exclusively abduction/adduction, anteversion/ retroversion, or internal/external rotation
  • Motor controls: For direct range of motion input
  • New patient: Restores the default settings for new patients
  • Patient chip card: For storage of the therapy parameters
  • Pauses: 0-30 seconds
  • Service menu: For service technicians
  • Side conversion: For easy, user guided conversion between right and left shoulder setup
  • Standby: Adjustment of inactive drives in parked position in Isolation mode
  • Therapy documentation: trend graph of the therapy progress
  • Timer1-59 minutes, 1-12 hours / continuous operation
  • Total therapy time: Added sum of all therapy sessions
  • Transport position: Moves the motors to transport position
  • Warm-up protocol: Gradual progression to the maximum range of motion